novinky vůči AP9617: -Command Line Interface replaces the Console Menu Structure for Telnet access to the card. This enables users to more easily run scripts via Telnet or locally via the configuration port. -Improved processing speeds which.. Číst dále

Záruka 24 měsíců Záruka
24 měsíců
Doprava zdarma nad 5.000 Kč Doprava zdarma
nad 2 000 Kč
(neplatí pro určené zboží)
Nevíte si rady? +420 720 946 222 Nevíte si rady?
Po–Pá 7:00 - 15:30
eshop + 420 702 521 521
servis + 420 603 235 182
eshop@elektrodvorak.cz

Popis produktu APC UPS Network Management Card 2 (AP9630)

novinky vůči AP9617: -Command Line Interface replaces the Console Menu Structure for Telnet access to the card. This enables users to more easily run scripts via Telnet or locally via the configuration port. -Improved processing speeds which allows users to quickly download logs and more efficiently upload security certificates. -Improved security with up to 2048-bit encryption. -Configuration port for local configuration of the UPS Network Management Card. Note: You cannot install this Network Management Card in a Symmetra PX 250 or Symmetra PX 550 UPS. Running a Multiple-UPS Configuration (Smart-UPS and Symmetra) A multiple-UPS configuration is also know as a "redundant UPS" configuration where one of several UPSs a) only partially shares the load or b) operates as a stand-by to back up a faulty unit. Specifically, PowerChute Network Shutdown can manage up to three Smart-UPS or Symmetra units (of the same model type) providing redundant backup power to a single server. In this configuration, each UPS in the system has its own Network Management Card (AP9630, or AP9631) with PowerChute Network Shutdown recognizing the entire configuration as a single UPS. Caution: In a multiple-UPS configuration, each UPS must have enough capacity to carry all the electrical load of the computer system. So, for example, if you had two UPSs in a multiple configuration, and one stops supplying power, the other UPS must have enough capacity to continue supplying power to protect the computer system. For a multiple-UPS configuration, you must have PowerChute Network Shutdown 2.2 or greater. See also Requirements. You can't upgrade to a multiple-UPS configuration from a previous version of PowerChute Network Shutdown: you must uninstall, install the new version, and reconfigure your options. With a multiple configuration, PowerChute Network Shutdown always recognizes and logs the events in the groups listed below (see the text on individual events in the List of Events section in Help.html): • Network communication lost events • UPS communication lost events • UPS off • UPS on battery events • Environmental Monitoring Card events • Runtime Exceeded For the Environmental Monitoring Card and Runtime Exceeded events, any actions you configured for the event will be instigated (see the Configuring Events section in Help.html). Notes: With multiple-UPS configurations: • PCNS always considers either a) a low battery condition or b) a UPS off condition as a critical event. • Two critical events in succession always cause a shutdown. In addition, with any of these configurations, a critical event will cause an immediate shutdown; no delay time will be counted.
Kód produktu 314354
Výrobce: APC
Záruka: 24 měsíců
Zázemí kamenných prodejen a profesionálního personálu

Zázemí kamenných prodejen a profesionálního personálu

Jsme ověřený obchod, Vaše data jsou u nás v bezpečí

Jsme ověřený obchod
Vaše data jsou u nás v bezpečí

Záruční i pozáruční servis zahradní techniky, aut, motocyklů, ATV

Záruční i pozáruční servis zahradní techniky, aut, motocyklů, ATV

Doprava zdarma při nákupu nad 10.000 Kč

Doprava zdarma při nákupu
nad 2 000 Kč
(neplatí pro nadměrné zboží)